Select products now available in our online store for North American customers.

SVLTR5000D DC-DC Converter

VPT’s SVL Series of DC-DC converters are mission proven in systems launching for LEO, MEO, GEO, and deep space missions. Qualified to MIL-PRF-38534 Class K on DLA SMDs, these off-the-shelf units help you get your system off the ground fast. View VPT’s space program heritage.

Combine our extensive family of DC-DC converters for space with VPT’s point of load converters for space to create a light weight, extremely efficient, space-ready power system.

Packing 40W in a miniature, lightweight case, the SVLTR DC-DC converter operates at full power throughout the extreme temperature range of -55°C to +125°C.

 

Features:

  • Dual outputs of ±5V,  ±12V, and ±15V
  • Up to 40W output power
  • Wide input voltage range: 30 to 60V continuous, 80V transient
  • Continuous operation over full military temperature range of -55°C to +125°C with no power derating
  • Very low output noise
  • Output voltage trim up +10%
  • Radiation immune magnetic feedback circuit
  • No use of optoisolators
  • Undervoltage lockout
  • Output overload and short circuit protection
  • Low profile (2.890″ x 1.125″ x 0.405″) and light weight (55g max) seam-welded hermetic metal packaging with industry standard pinout. Standard and optional side-flanged versions available.

Space-Level Characterizations:

  • Guaranteed TID performance to 60 krads (Si) including LDR.
  • SEE performance to 85 MeV/mg/cm2. Transients are fully characterized for cross section and magnitude.
  • Worst-case analysis, stress, radiation, reliability reports available.

Compliances and Certifications:

  • Qualified to MIL-PRF-38534 Class H and Class K, DLA SMD# 5962L22212
  • MIL-PRF-38534 element evaluated components
  • Meets MIL-STD-461 C/D/E/F conducted emissions requirements when used with a VPT EMI filter
  • Manufactured in a MIL-PRF-38534 Class H and Class K facility
  • MIL-STD-883
  • ISO-9001
  • RHA Level L

Summary Data

For complete specifications, please see the official datasheet.

To provide you with the most accurate data for the actual performance of this product once deployed, please note that the electrical performance data provided below is at Tcase = -55° C to 125° C, Vin= +28V +-5%, full load, unless otherwise specified.

Select a product to view its specifications:

ParameterConditionsSVLTR5005DUnits
MinTypMax
Input
Voltage
Continuous
Transient(1)
305060
80
Vdc
Output
Voltage
Full Load4.855.2Vdc
Output
Power
Vin: 15-50V0 30W
EfficiencyVin: 28V,
Full Load
7680 %
Input
Ripple
Full Load, 20Hz to
10MHz
 3050mApp
Output
Ripple
Full Load,
20Hz to 10MHz
 3060mVpp
Load
Regulation
No Load to
Full
 350mV
Line
Regulation
Vin: 15 to 50V 120mV

ParameterConditions SVLTR5012DUnits
MinTypMax
Input
Voltage
Continuous
Transient(1)
305060
80
Vdc
Output
Voltage
Full Load11.641212.36Vdc
Output
Power
Vin: 15-50V0 40W
EfficiencyVin: 28V,
Full Load
8084.5 %
Input
Ripple
Full Load, 20Hz to
10MHz
 3050mApp
Output
Ripple
Full Load,
20Hz to 10MHz
 2050mVpp
Load
Regulation
No Load to
Full
 350mV
Line
Regulation
Vin: 15 to 50V 120mV

ParameterConditionsSVLTR5015DUnits
MinTypMax
Input
Voltage
Continuous
Transient(1)
305060
80
Vdc
Output
Voltage
Full Load14.551515.45Vdc
Output
Power
Vin: 15-50V0 40W
EfficiencyVin: 28V,
Full Load
8084.5 %
Input
Ripple
Full Load, 20Hz to
10MHz
 3050mApp
Output
Ripple
Full Load,
20Hz to 10MHz
 2050mVpp
Load
Regulation
No Load to
Full
 150mV
Line
Regulation
Vin: 15 to 50V 120mV

(1) Transient time up to 1 second.