Select products now available in our online store for North American customers.

SVCL Inrush Current Limiter

The SVCL2800S Series of space qualified Inrush Current Limiters are operable over the full military (-55 °C to +125 °C) temperature range with no power derating. The SVCL2800S is designed to control the inrush current drawn by VPT’s EMI filters and DC-DC converters during turn-on. The SVCL2800S functions by limiting the rate of rise of its output voltage, and will also control the inrush current of discrete input capacitors.

The SVCL2800S Series of Inrush Current Limiters is radiation hardened and suited for use in low Earth orbit (LEO), medium Earth orbit (MEO), geostationary orbit (GEO), deep space, and launch vehicle programs.

Features:

  • High reliability
  • Wide input voltage range: 11 V to 50 V per MIL-STD-704
  • High input transient voltage: 80 Volts for 1 sec per MIL-STD-704A
  • Continuous operation over full military temperature range of -55°C to +125°C with no power derating
  • Compatible with external capacitance
  • Inhibit out
  • No use of optoisolators
  • Undervoltage lockout

Space Level Characterizations:

  • Guaranteed TID performance to 100 krad(Si) including ELDRS.
  • SEE performance to 85 MeV-cm2/mg. Transients are fully characterized for cross section and magnitude.
  • Worst case analysis, stress, radiation and reliability reports available.

Compliances and Certifications:

  • Qualified to MIL-PRF-38534 Class H and Class K, DLA SMD #5962-16216
  • MIL-PRF-38534 element evaluated components
  • MIL-STD-461 C/D/E/F when used with appropriate VPT EMI filter
  • Manufactured in a MIL-PRF-38534 Class H and Class K facility
  • MIL-STD-883
  • ISO-9001

Summary Data

For complete specifications, please see the official datasheet.

To provide you with the most accurate data for the actual performance of this product once deployed, please note that the electrical performance data provided below is at Tcase = -55° C to 125° C, Vin= +28V ±5%, full load, unless otherwise specified.

Select a product to view its specifications:

ParameterConditionsSVCL285R5SUnits
MinTypMax
Input VoltageContinuous
Transient - 1 sec.
112850
80
Vdc
Inrush CurrentPeak, Cout = 100µF
Peak, Cout = 250µF
  1.7
4.3
Apk
Output Current 0 5.5A
Output Power 0 100W

ParameterConditionsSVCL2811SUnits
MinTypMax
Input VoltageContinuous
Transient - 1 sec.
112850
80
Vdc
Inrush CurrentPeak, Cout = 100µF
Peak, Cout = 250µF
  1.7
8.5
Apk
Output Current 0 11A
Output Power 0 200W

(1) Transient time up to 1 second.
 