VPT’s SV Series of DC-DC converters are mission proven in systems launching for LEO, MEO, GEO, and deep space missions. Qualified to MIL-PRF-38534 Class K on DLA SMDs, these off-the-shelf units help you get your system off the ground fast. View VPT’s space program heritage.

Combine our extensive family of DC-DC converters for space with VPT’s point of load converters for space to create a light weight, extremely efficient, space-ready power system.

Measuring just approximately one inch square, the SVSA DC-DC converter provides up to 6W of output power from an efficient, light weight, space-saving package.

Features

  • Single outputs of 3.3V, 5V, 5.2V, 12V, and 15V
  • Up to 6W output power
  • Fault tolerant design with radiation immune magnetic isolation technology – no optoisolators
  • Extra-wide 15V to 50V input range per MIL-STD-704, transients to 80V for 1 sec
  • Extremely low profile (.270 inches) and light weight (15g) fully hermetic packaging
  • Wide case temperature operation of -55°C to +125°C with full performance over temperature range
  • Fixed switching frequency

Space-Level Characterizations

  • Characterized and guaranteed to 30krads (Si) per VPT’s RHA plan specified per MIL-PRF-38534, Appendix G, Level P with 2x margin
  • Characterized and tested for TID (total ionizing dose) at HDR (high dose rate) and LDR (low dose rate — ELDRS) per VPT’s RHA plan
  • SEE characterized for no destructive events up to LET = 44 MeV-cm2/mg including SEB, SEL, SEGR, and SEFI. No dropouts, shutdowns, latch up or burn out
  • Characterization and testing is performed at the critical semiconductor component piece-part level (RLAT) from traceable semiconductor lots
  • Characterization and testing also performed on the SVFL Series hybrid converter produced from the same traceable semiconductor lots evaluated during RLAT

Compliances and Certifications

  • Available to MIL-PRF-38534 Class K on DLA SMD #5962-11219
  • MIL-PRF-38534 Class H element evaluated components standard
  • MIL-STD-704 input voltage requirements
  • MIL-PRF-38534 Class H and Class K facility manufacturing
  • ISO-9001
  • MIL-STD-883 military and space environmental screening
  • Meets MIL-STD-461 C-F conducted emissions requirements when used with a DVMA28 EMI filter
  • VPT’s Radiation Hardness Assurance (RHA) Plan certified by DLA to MIL-PRF-38534 Appendix G

Summary Data

For complete specifications, please see the official datasheet.

To provide you with the most accurate data for the actual performance of this product once deployed, please note that the electrical performance data provided below is at Tcase = -55° C to 125° C, Vin= +28V +-5%, full load, unless otherwise specified.

ParameterConditionsSVSA283R3SSVSA2805SSVSA285R2SUnits
MinTypMaxMinTypMaxMinTypMax
Input VoltageContinuous
Transient(1)
152850
80
152850
80
152850
80
Vdc
Output VoltageFull Load3.253.303.354.9255.005.0755.1225.205.278Vdc
Output PowerVin: 15-50V0 40 50 5.2W
EfficiencyVin: 28V, Full Load6265 6568 6568 %
Input RippleFull Load, 20Hz to 10MHz 2550 3050 3050mApp
Output RippleFull Load, 20Hz to 10MHz  30  30 1030mVpp
Load RegulationNo Load to Full  50  50 1550mV
Line RegulationVin: 15-50V  15  15 215mV
ParameterConditionsSVSA2812SSVSA2815SUnits
MinTypMaxMinTypMax
Input VoltageContinuous
Transient(1)
152850
80
152850
80
Vdc
Output VoltageFull Load11.8212.0012.1814.77515.0015.225Vdc
Output PowerVin: 15-50V0 60 6W
EfficiencyVin: 28V, Full Load71767278%
Input RippleFull Load, 20Hz to 10MHz 3050 3050mApp
Output RippleFull Load, 20Hz to 10MHz 1030 1030mVpp
Load RegulationNo Load to Full 550 550mV
Line RegulationVin: 15-50V 215 215mV