VHRF10-28 EMI Filter

Bookmark and Share

The VHRF10 EMI filter is designed to filter the conducted emissions of multiple VHR series DC-DC converters up to its current rating, providing compliance to MIL-STD-461D-F for conducted emissions.

Features:

  • High reliability at low cost
  • Wide input voltage range: 0 to 50V
  • Up to 10.0 Amp maximum current
  • Operation over a -40 °C to +100 °C temperature range
  • 55 dB minimum attenuation at 500 kHz

Compliances and Certifications

  • MIL-STD-1275
  • MIL-STD-704
  • MIL-STD-461 C-F and EN55022 when used with an appropriate VHR DC-DC converter
  • MIL-STD-461C, CS01 and CS02, and MILSTD-461 C-F conducted susceptibility requirements when used with an appropriate VHR Series DC-DC Converter

Summary Data

For complete specifications, please see the official datasheet.

To provide you with the most accurate data for the actual performance of this product once deployed, please note that the electrical performance data provided below is at Tcase = -40° C to +100° C, Vin= +28V ±5%, full load, unless otherwise specified.

 

ParameterConditionsVHRF10-28Units
MinMinTypMax
Input VoltageContinuous Transient(1)02850
80
Vdc
Output Current(1)Vin: 0-50V0 10.0A
Noise Rejectionf=500kHz45  dB

(1) For 1 second, verified by qualification testing
(2) Derate linearly to 0° at 110°C

VHRF10-28
  • Related Videos


    Controlling Power Transients: MIL-STD-1275 and MIL-STD0704A Compliance Issues of DC-DC Converters

    MIL-STD-461 Conducted Emissions




Top