VXR100-2800D DC-DC Converter

Bookmark and Share

The VXR100-2800D is optimized for a broad range of applications from military ground vehicles to commercial and military aircraft and is intended for harsh environments including severe vibration, shock and temperature cycling. The VXR series is highly efficient with a low noise, fixed frequency, wide input voltage range topology. Two independent fully isolated outputs provide zero cross regulation and allow for multiple standard output voltage combinations.

The VXR series patent-pending epoxy encapsulated V-SHIELD® packaging is highly resistant to chemical, solvent and salt environments and is fully compatible with high volume manufacturing processes including wave solder, cleaning solvents, high pressure sprays and aqueous wash processes. A unique integral six-sided metalized shield improves system EMI compatibility. Dual sided conduction cooling coupled with reduced power dissipation simplifies system thermal design.

Features

  • Wide input voltage range: 11 V to 60 V
  • Continuous operation at 9 V after 11 V startup
  • 9 V to 100 V transient operation
  • Dual outputs of 3.3V, 5V, 7V, 12V, 15V and 18V
  • High efficiency
  • Rugged epoxy encapsulated V-SHIELD® package
  • Fully compatible with aqueous cleaning processes
  •  -55 °C to +105 °C operation
  • Integral six-sided metalized EMI shield
  • Dual-sided thermal conduction
  • 2000 V isolation
  • Fixed frequency
  • Low noise
  • Output current limit protection
  • Short circuit protection
  • Multiple standard output voltage combinations
  • Zero cross regulation

Compliances and Certifications

  • MIL-STD-1275 A-E
  • RTCA / DO-160-Section 16
  • MIL-STD-704 A-F
  • MIL-STD-461 C-F when used with an appropriate VXR EMI filter
  • RTCA / DO-160-section 18 and 21 when used with an appropriate VXR EMI filter
  • Testing to MIL-STD-883
  • J-STD-001, ISO-9001, IPC-A-610 Class 3 manufacturing

Summary Data

For complete specifications, please see the VXR100-2800D Datasheet.

To provide you with the most accurate data for the actual performance of this product once deployed, please note that the electrical performance data provided below is at Tcase = -55° C to +105° C, Vin= +28V ±5%, full load, unless otherwise specified.

ParameterConditionsVXR100-283R33R3DVXR100-280505DVXR100-281212DVXR100-281515DUnits
MinTypMaxMinTypMaxMinTypMaxMinTypMax
Input Voltage
Continuous92860112860112860112860Vdc
Output VoltageFull load3.223.33.384.8755.1311.71212.314.621515.38Vdc
Output Power11 V < Vin < 60 V
0 
400 500 500 50W
Output Power9 V < Vin < 11V0 400 42.50 42.50 42.5W
EfficiencyVin = +28 V Full Load
8185 8588 8487 8689 %
Input Ripple20 Hz to 10 MHz 4075 3575 60120 60120mApp
Output Ripple20 Hz to 10 MHz 70120 65110 50110 50110mVpp
Load RegulationNo Load to Full Load 420 420 220 220mV
Line RegulationVin: 11 V to 60 V 120 120 120 120mV



Top